6.6

Circulation pump (SICASYM)

6.6.1
Removal
Remove side panels and base plate
Loosen connection between stainless steel container and plastic
base pan, (2 screws at front and 2 screws at rear)
Raise container on the right side and tilt to the left
Secure container with an approx. 4 cm thick object
815_58300000003806_ara_en_e.doc – 30.01.12
Using a screwdriver, press the catch on the right side of the
circulation pump inwards
Rotate pump to the right
Remove pump