Solvent Push Feature - Graco ProMix 2KS Operation Manuals

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Solvent Push Feature

The Solvent Push feature enables the user to save
some mixed material by pushing it out to the gun with
solvent. The quantity saved is 50% of the potlife volume
entered in Advanced Setup Screen 1 on page 37. If
there are 2 guns, the smaller potlife volume is used.
Solvent Push requires an accessory solvent meter (MS).
Order Graco Part No. 16D329 S3000 Solvent Meter Kit.
See manual 308778.
1. See F
. 69. Install the solvent meter (MS) on the
IG
side of the fluid station, as explained in the ProMix
2KS Installation Manual.
2. To enable Solvent Push, select "Solvent" or "3rd
Valve," as desired. See Option Screen 2, page 35.
NOTE: If you are using a 3rd purge valve instead of the
solvent purge valve to run the Solvent Push feature,
connect the solvent supply line from the solvent meter to
the inlet of the 3rd purge valve.
NOTE: The system must be in Mix to initiate Solvent
Push.
3. Press and hold the Mix
to turn on Solvent Push. The green Mix LED will
light and the Recipe LED will blink. The system will
Key:
DVA Component A Dose Valve
DVB Component B Dose Valve
MS
Solvent Meter (required)
SPV Solvent Purge Valve
APV Air Purge Valve
SMC Solvent Meter Cable
SS
Solvent Supply Line
F
. 69. Solvent Push Setup
IG
312776K
4. The system will dispense solvent to push the mixed
NOTE: To manually interrupt Solvent Push, press the
Standby
3rd purge valve will close. To re-enter Solvent Push,
press the Mix
5. When the total solvent dispensed exceeds 50% of
6. Perform a manual purge or recipe change to purge
key for 5 seconds
NOTE: Once the system senses that solvent exceeds
50% of potlife volume, attempts to re-enter Solvent
Push will cause an Overdose A/B Alarm (E-5, E-6).
DVA is closed
close the Dose Valves (DVA, DVB) and open the
Solvent Purge Valve (SPV).
material out to the gun. The Booth Control display
alternately shows dashes and the percent remaining
(0-99%) of the 50% of the potlife volume.
key. The Solvent Purge Valve (SPV) or
key.
the potlife volume, the system will go into Standby
mode.
the remaining mixed material. This will clear the sys-
tem out of Solvent Push, allowing you to resume
Mix mode.
DVB is closed
SS
System Operation
MS
SMC
TI12556b
SPV is open
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix 3ks

Table of Contents