Lincoln Electric POWER FEED 84 SINGLE Operator's Manual page 73

Hide thumbs Also See for POWER FEED 84 SINGLE:
Table of Contents

Advertisement

POWER FEED 84, POWER FEED 84 DUAL
Parameter
P.507
UI Clear All Memories
Allows the operator to quickly set all memories to the default weld mode and welding parameters.
This parameter can only be accessed using Power Wave Manager software.
P.509
UI Master Lockout
Locks all user interface controls, preventing the operator from making any changes.
This parameter can only be accessed using Power Wave Manager software.
P.512
USB Options
This setting is used to enable and disable which USB options can be used on the feeder. Available selec-
tions are as follows:
(1) No Options = No USB options will be available for use. P.37 will not be available, and the USB prompt
will be disabled.
(2) Load/Save Mems & P-Nums, Create Key (All Options) = All USB options will be available for use in
P.37 and the USB prompt (if enabled)
(3) Load/Save Mems & P-Nums Only = Only the Load and Save User Memories and P-Numbers options
will be available for use in P.37 and the USB prompt (if enabled).
(4) Create Key Only = Only the Create USB Key option will be available in P.37 and the USB prompt (if enabled).
This parameter can only be accessed using Power Wave Manager software.
P.513
USB Prompt
This setting enables and disables the USB prompt. If enabled, the USB prompt will appear whenever a
USB drive is plugged into the system (the prompt is the same as P.37).
This parameter can only be accessed using Power Wave Manager software.
P.514
USB Key Lock
This setting turns on and off the USB-Key lock on a feeder.
When the feeder is locked, all encoders and buttons on the UI are disabled, Cold-Inch and Gas Purge are dis-
abled, and the feeder will not weld. Other feeders connected to the same Power Source will not be affected.
The only way to unlock the feeder is to plug a "USB Key" into the system. The key is a USB drive that has the
correct .key file in its "Lincoln\Keys" directory. A USB drive can be turned into a key by using the "Create USB
Key" option in P.37 on the feeder, or by creating the key through PowerWave Manager (future feature).
A .key file is specific to a feeder and the USB drive. A .key file that works on one feeder will not work on
another feeder. A .key file that works on one USB drive will not work on another USB drive. A USB drive
can have multiple .key files, making it a "USB Key" for multiple feeders.
This parameter can only be accessed using Power Wave Manager software.
USER DEFINED PARAMETERS
Name and Description
B-37
OPERATION
Range

Advertisement

Table of Contents
loading