POWER FEED 84, POWER FEED 84 DUAL
Parameter
P.106
View Ethernet IP Address
Used for viewing the IP address of Ethernet compatible equipment.
Press the Right Button to read the IP Address.
Press the Left Button to back out and exit this option. The IP address cannot be changed using this
option.
P.107
View Power Source Protocol
Used for viewing the type of power source the feeder is connected to.
Press the Right Button to identify the power source as either LincNet or ArcLink. Press the Left
Button to back out and exit this option.
P.500
View Lockout Parameters
Originally used to prevent inadvertent changes of secure setup parameters, P.500 was previously used
as a gateway to these parameters. Presently, this option does not exist in any setup menu.
P.501
Encoder Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire feed
speed, amps, volts or trim. The function of each upper knob depends on the selected weld mode.
When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right knob will
always function as an on/off switch.
This parameter can only be accessed using Power Wave Manager software.
P.502
Memory Change Lockout
Determines if the memories can be overwritten with new contents.
Unlocked = Memories can be saved and limits can be configured (default).
Fully Locked = Memories cannot be changed - saving is prohibited and limits cannot be re-
configured. Allow Saving Within Limits = Allows saving to memory when limits are enabled.
Only the nominal value is saved and only to the selected memory.
This parameter can only be accessed using Power Wave Manager software.
P.503
Memory Button Disable
Disables the specified memory button(s). When a memory is disabled, welding procedures cannot
be restored from or saved to that memory. If an attempt is made to save or restore a disabled
memory, a message will be displayed on the lower display indicating the memory number is dis-
abled. In multi-head systems, this parameter disables the same memory buttons on both feed
heads.
This parameter can only be accessed using Power Wave Manager software.
USER DEFINED PARAMETERS
Name and Description
B-35
OPERATION
Range
No, Yes