POWER FEED 84, POWER FEED 84 DUAL
Parameter
P.504
Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel selection is
locked and an attempt is made to change that parameter, a message will be displayed on the lower dis-
play indicating the parameter is locked.
• All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are unlocked.
• All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.
• Start & End Options Locked = The Start and End parameters on the Mode Select Panel are locked, all
others are unlocked.
• Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel, all others
Mode Select Panel settings are unlocked.
• Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are locked, all
others are unlocked.
• Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the Mode Select
Panel are locked, all others are unlocked.
• Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the Mode
Select Panel are locked, all others are unlocked.
This parameter can only be accessed using Power Wave Manager software.
P.505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without entering a passcode.
• No = The operator can change any set menu parameter without first entering the passcode even if the
passcode is non-zero (default).
• Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change any setup
menu parameters.
This parameter can only be accessed using Power Wave Manager.
P.506
Set User Interface Passcode
Prevents unauthorized changes to the equipment. The default passcode is zero which allows full access.
A nonzero passcode will prevent unauthorized: changes to memory limits, saving to memory (if P.502 =
Yes), changes to setup parameters (if P.505 = Yes).
If someone repeatedly enters an invalid passcode 5 times in a row, the passcode will be automatically
set to 9999, which is an invalid code and the interface can no longer be unlocked. PWManager is
required to reset the passcode or unlock the machine.
This parameter can only be accessed using Power Wave Manager software.
USER DEFINED PARAMETERS
Name and Description
B-36
OPERATION
Range
All MSP Options
Unlocked
All MSP Options
Locked
Start & End
Options Locked
Weld Mode Option
Locked
Wave Control
Options Locked
Start, End Wave
Options Locked
Start, End, Mode
Options Locked