Multi−Voltage Plug (Mvp) Connection - Miller DIVERSION 165 Owner's Manual

Wp - 17 torch
Hide thumbs Also See for DIVERSION 165:
Table of Contents

Advertisement

5-10. Multi−Voltage Plug (MVP) Connection
3
5
7
Selecting Plug
1
Power Cord Connector From
Welding Power Source
Select plug for power supply receptacle
available at site. Not all plugs shown are
provided as standard with unit.
2
Plug − NEMA Type 5−15P
3
Receptacle − NEMA Type 5−15R
(Customer Supplied)
.
A complete Parts List is available at www.MillerWelds.com
Selecting Plug
2
4
6
Connecting Plug To Power Cord
4
Plug − NEMA Type 5−20P (Optional)
5
Receptacle − NEMA Type 5−20R
(Customer Supplied)
6
Plug − NEMA Type 6−50P
7
Receptacle − NEMA Type 6−50R
(Customer Supplied)
!
Follow electrical service guide for
230 VAC in Section 5-4 and 5-5. Do
not use plug rating to size branch
circuit protection.
1
!
Do not cut off power cord connec-
tor and rewire. The power cord
connector and plugs will work
with standard NEMA receptacles.
Modifying power cord, connector,
and plugs will void product war-
ranty.
Connecting Plug To Power Cord
Align arrow on plug with arrow on power
cord connector. Push together.
Tighten threaded collar. As threaded collar
is tightened, push plug onto adapter until
collar is completely tight.
Connect plug to receptacle.
MVP Plug1 2010-10 / Ref. 803812-C