Advertisement

5-3. Shielding Gas Connections

Tools Needed:
5/8, 1-1/8 in.

5-4. Electrical Service Guide (Diversion 165)

.
All values calculated at 10% duty cycle.
.
Actual input voltage cannot exceed ± 10% of indicated required input voltage shown in table. If actual input voltage is outside of this range, damage
to unit may occur.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
Input Voltage (V)
Rated Maximum Supply Current I
Maximum Effective Supply Current I
Max Recommended Standard Fuse Rating In Amperes
Normal Operating Fuses
Min Input Conductor Size In AWG (mm
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG (mm
Reference: 2017 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" . See UL 248.
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amps), and UL class "H" ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
OM-263920 Page 14
.
A complete Parts List is available at www.MillerWelds.com
3
(A)
1max
(A)
1eff
1
2
Time-Delay Fuses
3
4
2
)
2) 4
2
1
.
Use argon shielding gas for
best performance.
1
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
2
Regulator/Flow Gauge
Connect regulator/flow gauge to
gas cylinder. Do not over tighten.
Connect gas hose to gas in fitting.
3
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour).
Ref. 805527 A
Elec Serv 2017−01
60 Hz 1-Phase
230 Volts AC
30
11.3
35
45
14
51 (16)
14