5-7. Connecting 230 Volts Input Power For Diversion 165 Models

Tools Needed:
OM-263920 Page 16
.
A complete Parts List is available at www.MillerWelds.com
1
6
L1
L2
3
4
9
1
10
L2
230 VAC, 1
!
!
!
See rating label on unit and check in-
put voltage available at site.
1
=GND/PE Earth
2
Ground
8
3
4
5
5
7
6
7
2
Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.
Connect input conductors L1 and L2
to disconnect device line terminals.
8
Select type and size of over-current
protection using Section 5-10 (fused
disconnect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout de-
vice, and place switch in the On posi-
tion.
9
10 Receptacle (NEMA 6-50R)
Connect plug to receptacle.
L1
Installation must meet all Na-
tional and Local Codes − have
only qualified persons make
this installation.
Always connect green or
green/yellow conductor
to
supply grounding terminal
first, and never to a line termi-
nal.
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Rating Label
Black And White Input
Conductor (L1 And L2)
Green Or Green/Yellow
Grounding Conductor
Input Power Cord.
Disconnect Device (switch
shown in the OFF position)
Disconnect Device Grounding
Terminal
Disconnect Device Line
Terminals
Over-Current Protection
Plug (NEMA 6-50P)
(Customer Supplied)
Ref. 805467-C