Operation
Operating Instructions 878-M PREMIUM - 02.0 - 02/2018
Changing the needle
Fig. 3: Inserting and replacing the needle - 1-needle machine
(1) - Needle bar
(2) - Lever
1. Turn the handwheel until the needle bar (1) reaches the upper
end position.
2. Draw the lever (2) in your direction to loosen the screw fixing
the needle.
3. Pull the needle out towards the bottom.
4. Insert the new needle.
5. Important: Align the needle so that the groove (3)
is facing the hook according to section (4) or (5). The needle
may not be oriented as shown at section (6).
6. Turn the lever (2) back to tighten the screw.
(3) - Groove
(4), (5), (6) - Orientation of needle