Calibration Steps; Serial Point Adjustment; Set Zero; Set Span - Fluke 2700G Calibration Manual

Reference pressure gauge
Hide thumbs Also See for 2700G:
Table of Contents

Advertisement

Calibration Steps

To calibrate the Product, apply the values shown in Table 3 for the correct
Product. If the Product fails to show the correct indication, adjustment is
necessary. Calibration can be done in any pressure unit that can be shown on
the Product display. Pressure units of psi and kPa are shown in Table 3 as
examples. If calibrating in other units, use points that are as close as possible to
those in Table 3.
Model
2700G-BG100K
0, -6, -12, -3, 0, 0, 3, 6, 9, 12, 15
2700G-BG200K
0, -6, -12, -3, 0, 0, 6, 12, 18, 24, 30
2700G-BG700K
0, -6, -12, -3, 0, 0, 20, 40, 60, 80, 100
2700G-BG2M
0, -6, -12, -3, 0, 0, 60, 120, 180, 240, 300
2700G-BG3.5M
0, -6, -12, -3, 0, 0, 100, 200, 300, 400, 500
2700G-BG7M
0, -6, -12, -3, 0, 0, 200, 400, 600, 800, 1000
2700G-G20M
0, 600, 1200, 1800, 2400, 3000
2700G-G35M
0, 1000, 2000, 3000, 4000, 5000
2700G-G70M
0, 2000, 4000, 6000, 8000, 10000

Serial Point Adjustment

Adjustment of the Product is done electronically with internal software. It is not
necessary to open the Product case. All calibration commands and adjustments
are done through the serial port connection. If the processes in the next sections
do not bring the Product into specification, then it will be necessary to send your
Product to Fluke Calibration for calibration adjustment.

Set Zero

After all connections are made, vent the Product to atmosphere and send this
command:
OFFSET_ADJ?
Note the value that is shown. When the pressure is stable, send:
OFFSET_ADJ N
N is the pressure given from the previous OFFSET_ADJ? command.

Set Span

Send the GAIN_ADJ? command.
Note the value shown. Use the correct pressure standard to input a value equal
to or near the noted value. When pressure is stable, send:
GAIN_ADJ N
Table 3. Calibration Tests
Calibration Points (psi)
Reference Pressure Gauge
Calibration Points (kPa)
0, -40, -80, -20, 0, 0, 20, 40, 60, 80, 100
0, -40, -80, -20, 0, 0, 40, 80, 120, 160,
200
0, -40, -80, -20, 0, 0, 140, 280, 420, 560,
700
0, -40, -80, -20, 0, 0, 400, 800, 1200,
1600, 2000
0, -40, -80, -20, 0, 0, 700, 1400, 2100,
2800, 3500
0, -40, -80, -20, 0, 0, 1400, 2800, 4200,
5600, 7000
0, 4000, 8000, 12000, 16000, 20000
0, 7000, 14000, 21000, 28000, 35000
0, 14000, 28000, 42000, 56000, 70000
Serial Point Adjustment
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents