N. Restarting the Appliance
Restart Process
1. When the unit has run out of fuel and the "feed error"
code is displayed, add pellet fuel to the hopper.
2. Dump the ashes and clinkers built up in the fire pot by
pulling the ash dump removal handle out several times.
Make sure clinkers have dropped into the ash pan then
return the handle to fully closed position.
3. If needed perform a manual feed; refer to section on
manual feed.
Restarting After a Power Failure
1. For an electrical disruption the appliance will start on
its own without need for MANUAL FEED - providing the
control system is asking for heat.
2. The appliance will always go through a normal shut-
down sequence before restarting.
O. Clear Space
NOTICE: Clearances may only be reduced by means
ap proved by the regulatory authority having jurisdiction.
Mantel: Avoid placing candles and other heat-sensitive ob-
jects on mantel or hearth. Heat may damage these objects.
P. Tuning
(Factory default setting is 5)
The function of tunning is to allow for variations in
elevation, venting and installation configurations,
and fuel types (hard wood/soft wood).
Figure 11.1
Rotating this dial will adjust the air/fuel ratio to the
appliance:
Increase the tunning number to increase the
flame height.
Decrease the tunning number to decrease
flame height.
Adjust 1 level at a time, allowing 15 minutes
for fire to stabilize before making another
adjustment.
A properly adjusted fire will have a bright, active
flame pattern that extends out of the fire pot approx-
imately 6 to 9 inches when burning on high. A prop-
erly adjusted fire will burn cleaner and have higher
efficiencies.