DHW tank
No.
Service valve
01
3 way diverting valve
02
Mixing Valve
03
Ciculation Pump
04
Drain Valve
05
T-Joint
06
Tundish
07
NOTE
• The table above contains the different components of the functional diagrams.

System configuration

• For the reliable performance and durability, all parts as listed below, including a relief valve, an expansion vessel, a drain valve
and pressure reducing valve , should be installed according to each national or regional standards. They are not supplied by
SAMSUNG.
– Pressure relief valve
– Expansion vessel
– Drain valve
– Tundish
– Expansion relief valve
– Pressure reducing valve
• Screw the thermistor socket in the foreseen threaded thermistor hole in the tank, use a thread sealant such as Teflon or similar
to make water tight.
• Apply contact glue to the thermistor and insert the thermistor as deep as possible in the thermistor socket. Fix using the nut
provided.
42
English
Note
No.
08
09
10
11
12
TW4
Tank Temp
Note
Expansion vessel
T-Joint
Expansion relief Valve
T-Joint
Pressure reducing valve with integrated check valve and strainer
Temperature Sensor for Mixing Valve
Temperature sensor for DHW tank