1-4

Specifications

This section gives the hardware specifications of the NA-series PTs.
1-4-1

General Specifications

Item
Rated supply
voltage
Allowable power
supply voltage
range
Allowable
momentary
power interrup-
tion time
Power con-
sumption
Ambient operat-
ing temperature
Ambient stor-
age temperature
Ambient operat-
ing humidity
Atmosphere
Pollution degree 2 or less: JIS B 3502, IEC 61131-2
Noise immunity
Vibration resis-
tance (during
operation)
Shock resis-
tance (during
operation)
Dimensions
Panel cutout
dimensions
Weight
Degree of pro-
tection
Battery life
NA-series Programmable Terminal Hardware User's Manual (V117)
1 Introduction to the NA-series Programmable Terminals
NA5-15W
NA5-12W
NA5-15U
NA5-12U
24 VDC
19.2 to 28.8 VDC (24 VDC ±20%)
Operation for momentary power interruption is not specified.
47 W max.
45 W max.
*1*2
0 to 50°C
*3
−20 to 60°C
*2
10 to 90%
Must be no condensation.
Must be free from corrosive gases.
2 kV on power supply line (Conforms to IEC 61000-4-4.)
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm half amplitude and 8.4 to 150 Hz with 9.8 m/s
in X,Y, and Z directions (Time coefficient of 10 minutes × coefficient factor of 10 = total time
of 100 min.)
Conforms to IEC 60028-2-27.
2
147 m/s
3 times each in X, Y, and Z directions
420 × 291 × 69 mm
340 × 244 × 69 mm
(W × H × D)
(W × H × D)
+1
+1
+1
× 268
392
mm
310
0
0
0
(horizontal × vertical)
(horizontal × vertical)
Panel thickness: 1.6
Panel thickness: 1.6
to 6.0 mm
to 6.0 mm
3.2 kg max.
2.3 kg max.
Front-panel controls: IP65 oil-proof type, UL Type 4X (at initial state)
To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of
the rubber packing.
Battery life: 5 years at 25°C
The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up
by a super capacitor for 5 minutes after removing the old battery.
(This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.)
Specification
NA5-9W
NA5-9U
40 W max.
290 × 190 × 69 mm
(W × H × D)
+1
+1
× 221
× 166
mm
261
0
0
(horizontal × vertical)
Panel thickness: 1.6
to 6.0 mm
1.7 kg max.
NA5-7W
NA5-7U
35 W max.
2
for 100 minutes each
236 × 165 × 69 mm (W
× H × D)
+0.5
+0.5
+1
× 141
mm
197
mm
0
0
0
(horizontal × vertical)
Panel thickness: 1.6 to
6.0 mm
1.3 kg max.
1 - 7