Transmission format
Select serial communication (RS485) transmission format (Data length, Parity).
Define the transmission format according to the master's (PLC etc.).
Press <ITEM/△>, <SHIFT/▽> to select.
[Set list] 8b-o (8bit odd), 8b-n (8bit none), 8b-E (8bit even)
Stop bit
Select serial communication (RS485) stop bit.
Response time
Set serial communication (RS485) response time of main unit.
When command is received, it sends response after setting response time passes.
* If Data Logger Unit (DLU) or Data Logger Light (DLL) is used as a master, set the response time to
5ms or more because DLU or DLL send the response after 1.1ms or less from receive a command
when transmission speed is set to 19200bps.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
*Select 50 or more when [645] is set for the protocol.
Press <ITEM/△>, <SHIFT/▽> to set.
[Set range] 1 to 99 ms (initial: 5)
increase
decrease
*Select [8b-E] when [645] is set for the protocol.
(initial: 8b-o)
*Select [1] when [645] is set for the protocol.
Press <ITEM/△>, <SHIFT/▽> to select.
[Set list] 1, 2 (initial: 1)
48