6.5.2 AP13500HG
When Tambient > 79ºF(26ºC) the unit runs in cooling mode. When Tambient < 68ºF(20ºC) the unit runs
in heating mode.
If the unit is operating in heating mode and 73ºF(23ºC) ≥ Tambient ≥ 68ºF(20ºC), the unit will stay in
heating mode. If the unit is not operating in heating mode the unit will change to dry mode.
6.6 Timer Mode
Timer ON is set with the unit OFF. The unit will turn ON when the set time is reached. The timer set range
is 0.5-24hr in 30-minute increments.
Timer OFF is set with the unit ON. The unit will turn OFF when the set time is reached. The timer set
range is 0.5-24hr in 30-minute increments.
6.7 Sleep Mode
Press the Sleep Button to enter sleep mode. The Sleep Mode can be activated when in Cool Mode or
Heat Mode and will not operate when in Fan Mode. When operating in Cool Mode, the Sleep function will
slowly raise the Temp Control by 4° Fahrenheit over the initial 2 hour Sleep Mode period. When operating
in Heat Mode (AP13500HG only), the Sleep function will slowly lower the Temp Control by 4° Fahrenheit
over the initial 2 hour Sleep Mode period. When the Sleep Mode is active, the LCD will continue to display
the Sleep Mode status.
6.8 Freeze Prevention Mode
Under freeze prevention mode the compressor stops running and the indoor fan operates at set fan
speed. After the evaporator thaws the unit will return to normal operation.
6.9 Compressor Protection Mode
If power is interrupted, the compressor will only restart after a 3 minute delay.
14