Addendum; Phase Conversion Kit - Jackson DynaTemp NB Service Manual

Dynatemp series dishmachine
Hide thumbs Also See for DynaTemp NB:
Table of Contents

Advertisement

ADDENDUM

DynaTemp units that are manufactured with the data plate above are able to be field-converted
to different phases and voltages. To accomplish this, your unit should have shipped with the
DynaTemp Phase Conversion Kit, part number 06401-003-71-71. This kit contains the appropriate
decals and schematics to apply to your unit once the conversion is complete.
All work should be performed only by Authorized Jackson Service Agents.
Steps:
1. Perform the appropriate wiring and component changes as necessary to achieve
the desired result. Reference Jackson technical manuals or contact technical service for
assistance.
2. Verify the Schematic is correct. If not, replace with the correct one from the kit.
3. At the power inlet, remove the "Wired For" decal and replace with the one that matches the
configuration of your machine.
57
SERIAL NUMBER:
MODEL: DYNATEMP
70BF RISE BOOSTER
WASH MOTOR
WASH HEATER
RINSE HEATER
TOTAL LOAD
70BF RISE BOOSTER
WASH MOTOR
WASH HEATER
RINSE HEATER
TOTAL LOAD
Made in the USA
Jackson WWS, Inc.
P.O. Box 1060
Barbourville, KY. 40906
(606) 523-9795
09905-004-29-08

PHASE CONVERSION KIT

XXXXXXXXX
208-230-460 Volt/60 Hz/3 Phase
208V
230V
3/4 HP
6.6 A
3/4 HP
6.6 A
3/4 HP
4.1 KW 11.4 A
5 KW 12.6 A
5 KW
10.5 KW 29.1 A 12.9 KW 32.4 A 12.9 KW 16.2 A
47.1 A
51.6 A
208-230 Volt/60 Hz/1 Phase
208V
230V
3/4 HP
6.6 A
3/4 HP
6.6 A
4.1 KW 19.7 A
5 KW 21.7 A
10.5 KW 50.4 A 12.9 KW 56.1 A
76.7 A
84.4 A
OPERATING PARAMETERS
MINIMUM WASH TEMPERATURE
MINIMUM RINSE TEMPERATURE
MINIMUM INCOMING WATER TEMPERATURE
70BF RISE BOOSTER
WASH CYCLE TIME
RINSE CYCLE TIME
FLOW PRESSURE
460V
1.8 A
6.3 A
24.3 A
150BF
180BF
110BF
40 SEC
11 SEC
8-12 PSI
07610-004-29-29-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

DynatempDynatemp s

Table of Contents