Section 3: Programming the Accord

An Introduction to Programming the Accord xpC

Getting In and Out of Programming Mode Using LCD keypad.

All zone and system programming must be carried out from the Programming Mode. To
enter Programming Mode enter the Engineer Code, press the # key and then the Ö key.
The Engineer Code is 9090 by default.
The keypad beeps twice, the Day icon (•) goes out and the Power icon (
keypad flashes to indicate that the system is in programming mode.
To exit Programming Mode press the # key followed by the Ö key. The power icon ( )
on the keypad stops flashing and the Day icon (•) activates.
During engineer programming mode, no communication to the central station will take
place. To perform an engineer reset enter the four digit engineer code (no need to enter
programme mode). Entering the programme mode during communication will abort the
communication.
Note: Pressing the Ö and # keys together within five seconds of power up defaults
the master code and the engineer code to factory settings.
Pressing the Ö and # keys together within five seconds of leaving the engineer
mode also defaults the master and engineer codes to factory settings. Pressing
any key within the five second period extend it for a further five seconds.
If Group 5 - Option 4 (Hotkey Enable) is enabled, pressing Ö and # activates
the keypad panic facility . The keypad panic facility will not operate within five
seconds of leaving engineer mode or powering up the system.

Defaulting Codes

To default the Master User Code and the Engineer Code press the Ö and # keys together
within five seconds of power up. Hold both keys down for approximately two seconds
until two beeps are emited. The Engineer Code defaults to 9090 and the Master Code to
1234.
Note: For important information on Ö and # key operation see the note above.

The Programming Format

An easy to use Programming Format has been adopted, to make Accord xpC programming
as simple as possible. Each system parameter has been allocated to a Programming group.
To programme a parameter select the programming group, select the parameter and enter
the desired value.
Accord xpC - July, 2001