Group 5 — Option 1 Audible Warning of AC Loss
When enabled (1) an audible indication is given from the keypad piezo that an a.c. mains
failure has occurred. The loudspeaker output LS also activates. Visual indication is always
given by the flashing
is given when the system is set.
This option defaults to 1 (enabled).
Note: When disabled no audible indication is given.
Group 5 — Option 2 Supplementary Entry
When disabled (0) an alarm condition occurs if the system has not been unset at the end
of the entry time.
When enabled (1) an internal only alarm occurs if the system has not been unset at the end
of the entry time (Trigger, External Bell and Strobe do not activate). The internal alarm
will run for 30 seconds. A full alarm will occur if the system has not been unset at the end
of this time.
This option defaults to 0 (disabled).
Group 5 — Option 3 System Reset for Alarm
This option determines how the system may be reset after an alarm condition:
0.
Customer.
1.
Engineer.
2.
Technistore.
3.
Engineer or Technistore.
Set to 0 (Customer): User code resets the system after alarm activations.
Set to 1 (Engineer): User code can cancel an alarm activation but the engineer code is
required to reset the system.
Set to 2 (Technistore): User code can cancel an alarm activation but a Technistore reset
number must be entered to reset the system.
Set to 3 (Engineer or Technistore): User code can cancel an alarm activation but either
the engineer code or a Technistore reset number must be entered to reset the system.
This option defaults to 3 (Engineer or Technistore).
Note: A system reset by the engineer for alarms does not affect Fire, PA Silent or PA,
these can be reset by a user code.
Technistore resets are overridden for set types in which communication is not
enabled, if communication is enabled at all (Group 7 – Option 6)
Group 5 — Option 4 Hotkey Enable
When enabled (set to 1) this option permits Assistance, Fire and Panic facilities to operate
via a double-push on the keypad.