STEP 1 - Installing the Rechargeable Backup Battery and
Power Connector
The control is designed to be placed on a desk/table top with the stand attached or
mounted to a wall using the back plate/cover.
1.
Remove the Control's Case Back.
®
2.
Install the ADTZWM (Wi-Fi
and Z-Wave
modules (if used).
2.
Connect the battery connector to the receptacle on the PC board.
3.
Insert the Battery Pack into the case.
4.
Secure the Battery Pack with the Battery Retainer using the Retaining Screw.
5a. Connect the power cable to the GND and +9V terminals on the AIO and to the +
and – terminals on the Power Supply. Refer to Table 1 for wire gauge and length.
Do not apply power at this time. OR
5b Connect the power supply connector to the receptacle on the AIO. Do not apply
power at this time.
NOTE: If using the optional wall mount configuration, skip to the wall mounting
procedure. If not, complete step 7.
6.
Install the Case Back onto the contorl and secure with the screw.
Optional ADTZWM and ADTLTE Communications Module Note: Refer to the Specific
Module Installation section in the online Installation & Reference Guide for instructions on
mounting this module.
SCREW
SCREW
COVER
ADTZWM
MODULE
EXT
INT
MACHINE
SCREW
ADTLTE
MODULE
RECEPTACLE
Table 1 – Wiring Guide
Maximum distance between
Wire Gauge
power supply and control
(AWG)
Up to 25 feet (7.62m)
# 22
Up to 45 feet (13.72m)
# 20
Up to 70 feet (21.34m)
# 18
Up to 110 feet (33.53m)
# 16
Mounting the Base to a Wall (Optional)
For wall mounting, perform to the following:
1.
Secure the Mounting Plate to the wall with 4 screws.
2.
Install the Tamper Screw as shown.
3.
Secure the Control to the Mounting Plate by aligning the slots on the Base and
sliding the unit down until locked in position.
4.
Secure the Control with the screw.
Ê800- - - - 24121^Š
Ê800
24121^Š
Ê800
Ê800
24121^Š
24121^Š
800-24121 5/18 Rev. A Part 1 (BETA)
®
) and/or ADTLTE Communications
SCREW
POWER
SUPPLY
BATTERY
CONNECTOR
TERMINAL BLOCK
Note: Use UL-listed limited energy
cable
STEP 2 - Setting up the Communication Links
Note: Do not connect to a receptacle controlled by a switch.
1.
Plug the power supply into a 24-hour, 110VAC unswitched outlet. Upon power-
up, the "Please Standby!" will be displayed on the home screen.
2.
Connect the Control to the local router.
STEP 3 - Registration Programming and Testing
On a laptop, PC or Smart Device, go to: https://alarmadmin.alarm.com.
IMPORTANT: Once the programming procedure has started and the unit is
powered up, do not remove power or disconnect the battery, nor open the case.
Disconnecting power or activating the tamper switch can cause unpredictable
programming results.
Radio Activation
Refer to the https://alarmadmin.alarm.com for radio activation.
Testing the System
The following test modes are available:
Walk Test
Communication Diagnostics
Enter Test mode (Walk Test)
1.
After entering Installer Tools Menu Mode, select the "Test" button.
2.
Select "Walk Test". The system enters Walk Test Mode and "Walk Test-Home To
Quit" is displayed
BATTERY
3.
Open each protected door and listen for three beeps from the keypad, followed
by the zone's Voice Descriptor. Identification of each faulted protection point
should appear on the display, and clear when the door is closed.
4.
Walk in front of the motion sensor and listen for three beeps and the zone's voice
descriptor.
5.
When testing is complete, select the Home button and enter the Installer Code.
6.
Press each key on the wireless key to confirm it performs its assigned function.
Specifications
Dimensions:
Voltage Input:
24-Hour Backup Battery:
Communication Formats:
Home Health Care Applications
IMPORTANT: In Home Health Care applications [UL1637] you must use pendant
model SiXMEDICAL. The maximum range is 50 ft.
Contacting Technical Support
DETAIL A
PLEASE, before you call Technical Support, be sure you:
READ THE INSTRUCTIONS!
• Determine that the power supply and/or backup battery are supplying proper
voltages.
• Verify your programming information where applicable.
• Note the proper model number of this product, and the version level (if known)
along with any documentation that came with the product.
• Note your ADT customer number and/or company name.
Having this information handy will make it easier for us to serve you quickly and
effectively.
For Documentation and Online Support
See Installation and Setup Guide P/N 800-24121 or higher, which can be
ordered by contacting Customer Service at 1-800-238-2727 (1-800-ADT-
ASAP). For technical support please call the ADT Product Support Group at
1-877-748-7628, option 3.
This system must be checked by a qualified technician at least once
every three (3) years
7.875" W x 5.75" H x 1.0" D
P/N 300-10260: White – 9VDC, 2.5A
P/N 300-10260-BK (Black) – 9VDC, 2.5A
P/N 300-10260-CAN (Canada) – 9VDC, 2.5A
P/N 300-10186: Rechargeable Backup Battery:
Lithium-ion battery pack rated at 3.6/4.2V, 7500 mAH
4-Digit Contact ID

Advertisement

loading

Summary of Contents for ADT ADT7AIO Series

  • Page 1 Customer Service at 1-800-238-2727 (1-800-ADT- Install the Tamper Screw as shown. ASAP). For technical support please call the ADT Product Support Group at Secure the Control to the Mounting Plate by aligning the slots on the Base and 1-877-748-7628, option 3.
  • Page 2: The Limitations Of This Alarm System

    Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. ADT Security Services, Inc. 1501 Yamato Road Boca Raton, FL 33431 Copyright © 2018 ADT Security Services...

This manual is also suitable for:

Adt5aio series