Group 7 — Option 5 Push-to-Set
If Push-to-Set is enabled (options 1 – 4), Full, Part or Night set exit times for the selected
will be set to infinity. For Full Set this overrides the value programmed in the Exit Time
option (Group 4 System Options — Option 1 Exit Time).
Setting of the system is terminated when a Push-to-Set zone is opened during the exit
time. There is a five second delay between the closing of the Exit Terminate zone and the
setting of the system.
Note: The operation (opening and closing) of Exit Terminate zones has no effect on
the system except during the setting procedure.
The options for Push-to-Set are:
0.
Push-to-Set not used.
1.
Push-to-Set on Full Set only.
2.
Push-to-Set on Full Set and Part Set.
3.
Push-to-Set on Full Set and Night Set.
4.
Push-to-Set on all set modes.
This option defaults to disabled 0 (Push-to-Set not used).
Note: Push-to-Set on Full Set is over-ridden when Final Contact is programmed
(Group 4 Option 1 = 0).
Group 7 — Option 6 When to Communicate
This option determines under which set conditions the panel communicates following,
Alarm, Abort, Verified Alarm and Tamper. This option has four modes of operation:
0.
Full Set only.
1.
Full Set and Part Set.
2.
Full Set and Night Set.
3.
All Sets (Full, Part and Night).
This option does not affect any other signals. Communication of Set/Unset is only sent
for Full Set conditions.
This option defaults to 0 (Full Set only).
Group 7 — Option 7 Line Fail
If this option is disabled (set to 0) there is no internal alarm or indication in the event of
a line fail condition being detected.
If this option is enabled (set to 1), a line fail condition will cause an internal alarm. An
audible indication is accompanied by the solid (
indication does not activate until 40 seconds after detection of the line fail.
The audible indication of the line fail is cancelled by the entry of a valid user code but the
( ) icon remains until 30 seconds after the Line Fail condition is restored.