Chassis Air Baffle Replacement - Lenovo ThinkSystem SR860 Maintenance Manual

Machine type: 7x69, 7x70
Hide thumbs Also See for ThinkSystem SR860:
Table of Contents

Advertisement

Figure 52. Drive installation
Step 4.
Rotate the drive-tray handle back to the locked position.
After installing the 2.5-inch hot-swap drive, check the drive status LED to verify if the drive is operating
correctly:
• If the yellow LED is lit continuously, it is malfunctioning and must be replaced.
• If the green LED is flashing, the drive is functioning.
Note: If the server is configured for RAID operation through a ThinkSystem RAID adapter, you might have to
reconfigure your disk arrays after you install drives. See the ThinkSystem RAID adapter documentation for
additional information about RAID operation and complete instructions for using ThinkSystem RAID
adapters.

Chassis air baffle replacement

Use this procedure to remove or install chassis air baffle.
Remove the chassis air baffle
Use this procedure to remove the chassis air baffle.
Before removing the chassis air baffle:
1. Read the safety information and installation guidelines (see "Safety" on page iii and "Installation
Guidelines" on page 59).
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
"Power off the server" on page 10).
3. If the server is installed in a rack, remove the server from the rack.
4. Remove the top cover (see "Remove the top cover" on page 146).
To remove the chassis air baffle, complete the following steps:
Watch the procedure. A video of the process is available: