Inputs:
-- GPS positioning data
-- Speed data from the GPS
-- Speed from the Pulse Log
-- Direction of speed from the Pulse Log
-- NMEA
-- 24V d.c. voltage supply
Outputs:
-- 2 x Heading (course bus or NMEA)
-- 1 x Heading (course bus)
-- Status signals
Optional feature
Additional Output Box 146--103
Input:
-- 1 x Heading (course bus)
Outputs:
Functions:
-- Integral Speed Error Correction (SEC)
Optional feature
-- Quick Settling with the Operator Unit
for Quick Settling
4201.DOC010102
Operator Manual
Compass Standard 22
Standard 22 Compact
STD 22 Compact as
a stand-alone system
designated CHn 1 and CHn 2
SEC (speed error correction)
System
Available
SSC--Interface
Step (6 steps/degree)
NMEA superfast 50Hz
and
STD 22 with other
system components
(Distribution Unit NG002/003 and
Operator Unit )
Inputs (via the Distribution Unit
only through a
"CAN bus" data bus system):
-- GPS positioning data
-- Speed data from the GPS
-- Speed from the Pulse Log
-- Leading sign for the speed
from the Pulse Log
-- NMEA
-- 24V d.c. voltage supply
-- DV--bus (alternative inputs for
speed/position at the
Distribution Unit
Optional feature:
-- Other (non Raytheon Anschütz)
heading sensors can be connected
to the Distribution Unit
Outputs (at STD 22 compass):
-- 2 x Heading (course bus or NMEA)
-- 1 x Heading (course bus)
-- Status signals
SEC(speed error correction)
System
Available
Heading (Course bus or
NMEA) without SEC
Outputs (Distribution Unit
NG002/003):
-- 1x RS232 for courseprinter
-- 1x rate of turn (analog)
-- 12 x Heading (course bus or NMEA)
-- DV--bus
-- Status signals
Functions: (Compass STD 22)
-- Integral Speed Error Correction
(SEC)
-- Quick Settling via the operator unit
2