Operating condition 1 "Fan failure"
This condition is generated if the fan does not switch itself on as a result of the
temperature of the supporting liquid (it should switch on when the supporting liquid
reaches 51C).
Whether the fan is operational or not is registered from the fan's current consumption; it
therefore follows that the fan is defective if this condition is displayed.
To prevent overheating due to fan failure, it is recommended that you do the following:
Continue this until operating condition 1 stops.
It is essential that the fan be replaced at the earliest opportunity.
NOTE: A critical situation occurs, if the ambient temperature is extremely high
Edition: February 2015
Operator Manual
Compass Standard 22
and
Standard 22 Compact
-- Check whether the fan screen is covered and check to see that air can enter
the enclosure unhindered at the base.
-- If necessary cool the outer sphere using an external fan.
and condition 3 is displayed "Temperature of supporting liquid more than 60C".
Constant high temperature may effects to the life cycle of the gyro compass.
A higher temperature for a short moment has no importance.