Raytheon Standard 22 Compact Operator's Manual page 47

Gyro compass
Table of Contents

Advertisement

-- Open the ventilation outlet (Figure 15 /1), the supporting liquid screw (Figure 15 /3)
and the distilled water screw ( Figure 15 /2).
-- Fill in distilled water (only distilled water from Raytheon Anschütz,
part number 148--398, one 230cm
supporting liquid until the measuring cone shows "Level O.K.", see Figure 16 .
-- Fill in the remaining content of the bottle into the inlet for distilled water until the
Dip--Stick shows a level according to Figure 17 .
-- Close all in-- and outlets, if applicable use new sealing rings.
-- Place the outer sphere in the compass enclosure.
-- Hold the outer sphere with both hands and guide it under the snap closures on the
pendulum joint.
-- Using the thumbs, press down and engage the two snap closures.
-- Carefully turn the outer sphere through 90 and repeat the process with the other two
snap closures. The outer sphere is now fastened to the pendulum joint.
-- Switch on the follow--up function again (DIP switch 7 into the lower position,
see Figure 18 ).
-- Close the door of the enclosure and fasten it with screws, paying attention to the
earthing strip.
Edition: February 2015
Operator Manual
Compass Standard 22
and
Standard 22 Compact
--
Pay attention to the two locking pins on the
closure.
After this procedure is finished, it is strongly recommended to
observe the heading for a while (30 minutes), because of
stimulation of the gyrosphere (caused by a slight,
unintentional horizontal inclination).
3
bottle) into the inlet for
41
Compass
Standard 22
4102.DOC010102