Defective Sensing-Ink; Defective Sensing-Paper - Samsung SCX-1100 Service Manual

Mfp
Hide thumbs Also See for SCX-1100:
Table of Contents

Advertisement

Troubleshooting

4-3-11 Defective Sensing-ink

• Description
The ink is put in the set, but it cannot sensed.
• Location
1.Cartridge ASS'Y
Check and Cause
1. Check if the cartridge is installed in the cartridge box
properly.
(It makes a click sound normally when it is normal.)
2. Check if the cartridge box is operated normally.
3. Check if there is an alien matter in the Dimple contact
point of HEAD of CARTRIDGE BOX

4-3-12 Defective Sensing-paper

• Description
The recording papers are put in already, but it cannot be sensed.
• Location
1.Main B'D
Check and Cause
1. Check if the ENTER key on the OPE panel is pressed.
4-10
2.Main B'D
2. LF Motor
Solution
1. Even after the cartridge is installed normally, it still can-
not sense, then try to replace the Main B'D.
2. In case the cartridge box is not moved from side to side,
check the Flat Cable connection between the Main PBA
& Frame Home Unit, and even after being connected
properly, if it is still not improved, then try to replace the
cartridge ASS'Y.
Solution
1. Refer to "Defective Paper Feed".
2. Even if the ENTER key on the OPE panel is pressed, it
still cannot sense, then try to replace the Main B'D and
LF Motor in sequence.
Notes:
The SCX-1100 Product has no paper sensor, instead it
displays ERROR when it cannot pick up the paper.