Cornelius 2232 Installation Instructions Manual page 31

Ice/soft drink post mix dispenser
Table of Contents

Advertisement

Trouble
NO PRODUCT DISPENSED
FROM ONE DISPENSING
VALVE.
ONLY CARBONATED WATER
DISPENSED.
ONLY SYRUP DISPENSED.
DISPENSING VALVE WILL
NOT DISPENSE ANY
PORTION CONTROL SIZE
DRINK.
NO RESPONSE FROM ONE
OF THE PORTION CONTROL
SWITCHES OR THE
CANCEL/POUR SWITCH.
Probable Cause
A.
Broken or disconnected wiring.
B.
Inoperative dispensing valve.
Inoperative dispensing valve.
C.
Inoperative portion control.
A.
Quick disconnects not secure
on syrup tanks.
B.
Out of syrup.
C.
CO
regulator for syrup tanks
2
not properly adjusted.
D.
Inoperable dispensing valve.
E.
Dispensing valve syrup flow
control not properly adjusted.
F.
Dispensing valve syrup flow
control, syrup tank quick
disconnect, or syrup lines
restricted.
A.
Plain water inlet supply line
shutoff valve closed.
B.
Carbonator power cord
unplugged from electrical
outlet.
C.
Carbonator CO2 regulator not
properly adjusted.
A.
Portion control not properly
adjusted.
B.
Portion control cover electrical
wiring disconnected.
C.
Inoperable portion control.
A.
Inoperable portion control.
27
Remedy
A.
Connect wiring or have repaired.
B.
Have dispensing valve repaired.
C.
Replace portion control cover.
A.
Secure quick disconnects on
syrup tanks.
B.
Replenish syrup supply as
instructed.
C.
Adjust syrup tank CO
as instructed.
D.
Have dispensing valve repaired.
E.
Adjust dispensing valve syrup
flow control (Water–to–Syrup
"Ratio") as instructed.
F.
Sanitize syrup system as
instructed.
A.
Open plain water inlet supply line
shutoff valve.
B.
Plug carbonator power cord into
electrical outlet.
C.
Adjust carbonator CO2 regulator
(Reference manual provided with
carbonator).
A.
Adjust all portion sizes on
dispensing valve as instructed.
B.
Connect portion control cover
electrical wiring.
C.
Replace portion control cover.
A.
Replace portion control cover.
regulator
2
91633