Figure 11. Normal Ice Portion-Control And Extra Ice Adjustment Mode - Cornelius 2232 Installation Instructions Manual

Ice/soft drink post mix dispenser
Table of Contents

Advertisement

Normal Ice Portion Control
Adjust Mode
Normal Operating Mode
(Solid Green LED)
Press Y & B at the same time, then
immediately release
LED Flashing Red/Amber
Press Y &B at the same time, then
immediately release
Normal Portion-Control Mode
(Solid Amber LED is on)
Extra Ice Adjustment Mode
Normal Operating Mode
(Solid Green LED)
Press Y & B at the same time,
then immediately release
LED Flashing Red/Amber
Press Y & B at the same time
then immediately release
Solid Amber LED is "ON"
Press Y &B at the same time,
then immediately release
Extra Ice Adjustment Mode
(Solid red LED is "ON")
Note:
To return ice portion control to factory settings, the ice portion control must be in the Normal Ice Adjustment Mode (Solid Amber
LED). Then, at the same time, press and hold the small and extra large buttons for 1 second. The LED will go from amber to red and back
to amber which signals that the portion sizes have been returned to the factory settings.
FIGURE 11. NORMAL ICE PORTION–CONTROL AND EXTRA ICE ADJUSTMENT MODE
91633
This mode is used to adjust
ice portion sizes
IMPORTANT If no adjustments are made within
60 seconds, ice dispensing will return to normal oper-
ating mode.
L.E.D.
Indicator
Light
Decrease
1. Press and hold the desired ice portion selection but-
ton to be adjusted.
2. While holding the portion selection button, momen-
tarily press the increase (Y) or decrease (B) to change
the amount of ice dispensed. Each time the B or Y is
pressed the ice portion will change. A slow flashing
LED means the portion is set at minimum. A fast
flashing LED means the portion is set at maximum.
3. After adjustment has been made, release the portion
selection button. The green LED will flash for 5 se-
conds. Within this 5 sec., press cup size button being
adjusted to take a sample. After 5 seconds the LED
will return to solid amber (Normal adjustment mode).
A solid red LED will be displayed briefly after dis-
pensing a sample if the ice gate cylinder switch was
shorted; a flashing red LED indicates an open in the
ice gate cylinder switch wiring or an ice gate binding
condition.
4. Repeat process until proper portion size is obtained.
Start Here
No
Go to the next ice portion
and repeat programming
Momentarily press B and Y at the
same time to go to "Extra Ice Adjust
Mode". Red LED will be turned on.
Momentarily press B and Y at the
same time to return to the normal
operating mode. Green LED will be
turned on.
Same adjustment procedure as normal
ice portion control adjust mode
18
Adjustment Panel
Y
B
Is the ice portion set as desired?
No Adjustment
Increase
Yes
Adjust

Advertisement