Trouble
DISPENSED PRODUCT
CARBONATION TO LOW.
(con't)
DISPENSED PRODUCT
COMES OUT OF
DISPENSING VALVE CLEAR
BUT FOAMS IN CUP.
DISPENSED PRODUCT
PRODUCES FOAM AS
PRODUCT LEAVES
DISPENSING VALVE.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES.
91633
Probable Cause
C.
Water, oil, or dirt, in CO
supply.
A.
Ice used for finished drink is
subcooled.
B.
Insufficient ice supply in
dispenser ice bin.
C.
Oil film or soap scum in cups
A.
Carbonator primary CO
regulator CO
pressure set to
2
high for existing water
conditions or temperature.
B.
Syrup over carbonated with
CO
as indicated by bubbles in
2
inlet syrup lines leading to
dispenser.
C.
Dispensing valve restricted or
dirty.
D.
Tapered nylon washer inside
carbonated water line swivel
nut connector distorted
restricting carbonated water
flow.
E.
Dirty water supply.
Note: If water supply is dirty, be sure to flush lines and carbonator complete-
ly. It may be necessary to remove lines to carbonator tank, invert tank and
flush tank and all inlet lines to remove any foreign particles or dirt.
A.
Dispenser rocker–type power
switch in OFF position.
B.
No electrical power to
dispenser.
C.
Disconnected or broken wiring
to dispensing valves.
D.
Loose ground connection.
E.
Inoperative dispenser
transformer
26
C.
Remove contaminated CO
2
Clean CO
regulator, etc) using a mild
detergent. Install a clean CO
supply.
A.
If using purchased ice allow ice to
melt slightly before using.
B.
Replenish ice supply as
instructed.
C.
Use clean cups.
A.
Reduce carbonator CO
2
setting.
B.
Remove syrup tanks quick
disconnects. Relieve tank CO
pressure, shake tank vigorously,
then relieve tank CO
many times as necessary to
remove over–carbonation.
C.
Sanitize syrup system as
instructed.
D.
Replace nylon washer. Make
sure it is properly seated.
E.
Check water filter. Replace
cartridge.
A.
place power switch in ON
position.
B.
Plug in dispenser power cord, or
check fuse or circuit breaker.
C.
Connect or replace wiring.
D.
Have ground connection repaired.
E.
Have transformer replaced.
Remedy
.
2
system (lines,
2
2
regulator
2
2
pressure as
2

Advertisement

Table of Contents