Download Print this page

BEA LZR-WIDESCAN Quick Start Manual page 4

Motion, presence, and safety sensor for industrial doors
Hide thumbs Also See for LZR-WIDESCAN:

Advertisement

5
TEACH-IN: INSTALL
The teach-in zone (square in front of the 2 visible spots) should be completely free and flat.
This teach-in must be launched each time one of the sensor angles has been changed.
Make sure the protection film is removed.
1. Launch a teach-in by LCD or remote control (Quick Start > Teach-in > Install).
LCD
2. Clear the teach-in zone in front of the sensor.
The learning process starts. Position, angle, and height are learned; the background
is analyzed and the teach-in ends successfully. If this is not accomplished, refer to the
TROUBLESHOOTING section in the user's guide (75.5916).
...
MOTION
....
PRESENCE
..
SAFETY
6
CLOSING THE SENSOR
a
Lock the lateral angle by firmly
fastening the angle lock screw.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325).
Verify that all appropriate industry signage and warning labels are in place.
General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.BEAinc.com
Page 4 of 4
Page 4 of 4
QS
Quick Start
TeachIn
In-Out
Presettings
SETTINGS FOR 3 MAIN FUNCTIONS
WIDTH
DEPTH
WIDTH
DEPTH
WIDTH
DEPTH
b
Reclip the sensor cover horizontally
and close it as indicated.
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
TeachIn
Install
Factory value: 240 in
000 – 999
000 – 999
Factory value: 287 in
Factory value: 240 in
000 – 999
000 – 999
Factory value: 80 in
Factory value: 240 in
000 – 999
000 – 999
Factory value: 16 in
REMOTE
1
2
3
A
4
5
6
B
CONTROL
7
8
9
C
F1
0
F2
D
c
Lock the cover by turning the
lock screw clockwise.
75.5917.02 LZR-WIDESCAN QSG 20171220
75.5917.02 LZR-WIDESCAN QSG 20171220
5

Advertisement