Download Print this page

BEA LZR-WIDESCAN Quick Start Manual page 2

Motion, presence, and safety sensor for industrial doors
Hide thumbs Also See for LZR-WIDESCAN:

Advertisement

3
MOUNTING & WIRING
Install the sensor in the left corner (recommended) or the center of
the door as high as possible (max. 19'6").
The size of the detection field depends on the mounting height.
a
Remove the rotation plate from the sensor and secure
it to the wall. You can also install the sensor directly
without using the rotation plate.
c
Orient the sensor horizontally to the left and secure
the sensor to the rotation plate.
*
*
COM
NO
NC
*
Connect the wires accordingly.
Page 2 of 4
Page 2 of 4
b
Verify if the angle lock screw is positioned as indicated.
Unscrew if necessary.
d
Plug the connector and pass the cable through the
cable passage without making a loop.
POWER
OUTPUT 1
OUTPUT 2
RELAY
TEST
* output status during non-detection
** default value (see IN/OUT)
H
5
Launch teach-in after
angle adjustment.
All presence/safety
outputs are activated.
75.5917.02 LZR-WIDESCAN QSG 20171220