4
ANGLE ADJUSTMENT
Power the sensor. The LCD screen shows the detection display.
Activate the 2 visible laser spots by double-clicking OK or using the remote
control sequence shown to teh right.
The visible laser beams stay activated for 15 minutes or can be turned off by
PRESS
2X
double-clicking OK.
Do not look directly into the laser emitter or the visible red laser beams.
Remove the blue protection film from the laser window.
Make sure the curtain is parallel to the door by adjusting one or both screws on the side.
Position the curtain closer to or farther away from the door by turning the screw at the top.
Launch the POSITION WIZARD to position the detection field correctly in front of the door.
LONG
1. Push and hold OK to launch the POSITION WIZARD.
2. Rotate the sensor in order to align the center of the red spots with the center
of the door. Push OK.
3. Rotate the sensor until the LCD screen validates the position. Push OK to exit.
Lock the sensor position by tightening the angle lock screw (see step 6A).
75.5917.02 LZR-WIDESCAN QSG 20171220
75.5917.02 LZR-WIDESCAN QSG 20171220
AWAY
CLOSER
1
2
3
A
4
5
6
B
7
8
9
C
F1
0
F2
D
When the safety
function is required,
the red spots should be
as close to the door as
possible.
Negative angles reduce
the depth of the
detection fields.
OK
The size of the detection
field depends on the
mounting height:
DETECTION FIELD
6 ft
7.2 × 7.2 ft
9 ft
10.8 × 10.8 ft
12 ft
14.4 × 14.4 ft
15 ft
18 × 18 ft
Page 3 of 4