SPECIAL MODE

Special mode setting button

b Press the ON/STANDBY button to turn on while pressing both buttons A and B at the same time.
Mode
Version display
(μcom/DSP Error Display)
Displaying the protection history mode
IInitialization mode
(Remove settings for Installer Setup.)
Initialization mode
(Includes settings for Installer Setup)
Mode for switching tuner frequency step
Mode for preventing remote control
acceptance
Panel lock mode
Panel lock mode
(Remove Master volume)
Cancellation of panel lock mode
Installer Setup mode
NOTE:
If " S " is displayed on the fl uorescent display, the unit is set to the special developer's mode and RS-232C
communications are not possible.
Press and hold in the "STATUS" and " i " buttons for over 3 seconds with the power turned on to turn the " S " display
off. RS-232C communications are now enabled.
b When power is turned on, pressing both buttons A and B at the same time for 3 seconds or more.
Mode
DUAL BACKUP MEMORY (Backup)
DUAL BACKUP MEMORY (Recovery)
DUAL BACKUP MEMORY
(Backup Clear)
ON/STANDBY
Button A
Button B
STATUS
RETURN
STATUS
MENU
SURROUND
AUTO
MODE
PURE
CURSOR UP
DIRECT
SURROUND
PURE
MODE
DIRECT
STATUS
ENTER
AUTO
DISPLAY
PURE
DISPLAY
DIRECT
CURSOR
DISPLAY
DOWN
CURSOR
MENU
Button A
Button B
SLEEP
ENTER
SLEEP
MENU
SLEEP
AUTO
PURE DIRECT
DISPLAY
AUTO
STATUS
SURROUND MODE
Serial No. and fi rmware versions such as Main, Sub, DSP are
displayed in the FL manager. Errors are displayed when they
occur. (Refer to 18 page)
Displaying the protection history
(Refer to 21 page)
Backup data initialization is carried out.
(Remove settings for Installer Setup)
Backup data initialization is carried out.
(Includes settings for Installer Setup)
---N model only---
Change tuner frequency step to FM:200kHz/AM:10kHzSTEP
Operations using remote control are rejected.
(Mode cancellation: Turn off power and execute the same
button operations as when performing setup.)
Operations using main unit panel buttons or master volume are
rejected.
Operations using main unit panel buttons are rejected.
Panel lock mode is cancelled.
Access Remote Maintenance mode via the internet.Installer
LEFT
Setup is displayed on GUI/Option Menu.
Backup of DUAL BACKUP MEMORY is performed.
(Refer to 23 page.)
Recovery of DUAL BACKUP MEMORY is performed.
(Refer to 23 page.)
Backup of DUAL BACKUP MEMORY is cleared.
(Refer to 23 page.)
CURSOR
MENU
RETURN
SLEEP
17