Manually Activate All Valve Test; Adjust Watering - Toro EVOLUTION User Manual

Ag controller
Table of Contents

Advertisement

Available languages

Available languages

Manually Activate All Valve Test

Step 1
– Press the
WATER NOW button.
Step 2
– Use the Up
or Down
WATER NOW
SCHEDULE A
SCHEDULE B
VALVES
ALL VALVE TEST
02:00
Step 3
– Use the Up
or Down
Note:
e
EVOLUTION
1. All active valves will run the speci ed runtime duration. Fertilizer pumps (FP1 and FP2) are not activated during ALL VALVE
TEST.

Adjust Watering

Adjust Watering is used to increase or decrease the amount of time a valve(s) will water.
Note: Fertigation runtime is not a ected by water adjustment. During water adjustment, the valve runtime could get adjusted with a
shorter runtime than the Fertigation runtime. A ! symbol will appear on the valve runtime as a warning that the fertigation time is longer
than the posted valve runtime. However, the Fert Pump will stop when the irrigation valve closes, even if it is programmed to run longer
that the irrigation valve.
– Press the
ADJUST WATER button.
Step 1
Step 2
– Use the Up
or Down
ADJUST WATER
SCHEDULE A
SCHEDULE B
Step 3
– Press the Right
arrow to navigate to the next screen. Choose from the two options.
ADJUST WATER
ALL VALVES (%)
BY VALVE
Option 1
"All Valves (%)" – Runtimes for All valves on the selected schedule will increase/decrease by the selected percentage. Adjust
the watering percentage from 150% to -95% or OFF.
– Press the Right
– Use the Up
or Down
– Press SELECT
All runtimes for selected schedule will now re ect the percent adjustment.
Example: Original runtime = 10 minutes
Adjustment of +50% = 15 minutes
Adjustment of -50% = 5 minutes
Option 2
BY VALVE – Runtimes may be adjusted in minutes for individual valves.
– Use the Up
or Down
– Press SELECT
ADJUST WATER
VALVE1
01:00:00
VALVE2
10:00:00
– Use the Up
or Down
– Press SELECT
– Use the Up
or Down
runtime to 24 hours.
arrows to navigate to ALL VALVE TEST. Press the Right
arrows to assign a runtime. Press SELECT
®
AG
controller will sequentially water all active valves (valves with runtimes) starting with Valve
arrows to select the schedule you want to adjust.
arrow to select this option.
SCHEDULE A
arrows to increase or decrease the runtime percentage (%).
.
arrows to select the BY VALVE menu.
to select.
arrows to select the valve you want to adjust.
to access the runtime.
arrows to increase or decrease the amount of runtime. Adjustment can be made from no
.
ADJUST WATER
–––
arrow or SELECT
.
13