Pressure Relief Procedure - Graco HFR Setup And Operation Manual

Hydraulic, plural-component, fixed-ratio proportioner for pouring and dispensing sealants and adhesives and polyurethane foam
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Pressure Relief Procedure

1. Shut off feed pumps and agitator, if used.
2. Turn PRESSURE RELIEF/DISPENSE valves (SA,
SB) to PRESSURE RELIEF/CIRCULATION
Route fluid to waste containers or supply tanks.
Ensure gauges drop to 0.
SA
3. For models with an dispense valve with a safety
lock, engage gun safety lock.
4. Relieve pressure in dispense valve. See dispense
valve manual.
313997ZAA
.
SB
ti9879a1
Pressure Relief Procedure