Fault Finding Tests - Rheem 874W27NF Service Manual

27 water star. continuous flow water heater with auxiliary hot water storage tank
Table of Contents

Advertisement

Fault Finding Tests 18 - 23

Test 20 & 21
BK R
4 5 6
6
5
4
3
2
1
Conduct test with water flowing
Using a multimeter set on the DC volts scale,
measure the voltage at connector N whilst
plugged into PCB.
Test
Check Point
20
7 Red - 8 Black
21
2 White - 8 Black
TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by
Tests 18 & 19
Using a multimeter set on the DC volts scale, measure the
voltage at connector J whilst plugged into PCB.
Test
18
19
BR
Y
G W
SW1
SW2
7
8
Y
N
R
9
BK
4
8
BK
BK
3
7
6
R
R
2
6
G
5
P
1
5
Y
4
4
3
BL
3
2
O
W
1
1
BR
Measured Value
DC8 – 16V
DC8 – 16V
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
Conduct test with water flowing
Check Point
6 White – 4 Blue
3 Red – 4 Blue
(or measurement by pulse
1 Yellow – 4 Blue
Test 22 & 23
W
Conduct test with water flowing
Using a multimeter set on the DC volts scale,
measure the voltage at connector M whilst
plugged into PCB.
Test
Check Point
22
7 Red - 8 Black
23
2 White - 8 Black
Measured Value
DC144 - 192V
DC12 - 18V
DC4 - 10V
counter of not less than
4800 pulses per minute)
SW1
SW2
SW3
N
M
O
9
8
BK
4
8
BK
7
R
3
7
R
6
G
2
6
G
5
Y
Y
4
BL
3
O
W
2
W
1
BR
1
BR
Measured Value
DC8 – 16V
DC8 – 16V
40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: