Fault-Finding Tests 5 - 7
Conduct test with no water flow.
Using a multimeter set on the DC volts scale,
measure the voltage between 3 Red and 2 Black
at terminal S on the control PCB.
Normal voltage should be between DC11 – 17V.
Remove the flow sensor turbine. Refer to „Flow Sensor Turbine‟ procedure on page 53.
Check for excessive wear of turbine or blockage by foreign material such as thread tape. The power
must be isolated during water flow sensor removal.
TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10