NO ERROR CODE FAULT FINDING

Is the unit used as
an in-series gas
booster?
YES
TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by
Read
NO
maintenance
information 1y
1y = Water flow
detected by water
flow sensor
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
Is 1y displaying a
flow greater than
YES
2lpm?
NO
Is water flow
through unit greater
NO
than 2lpm?
YES
Is the voltage
between terminals 2
& 3 at connector S
NO
normal?
Test 5
YES
Is the voltage
between terminals 1
& 2 at connector S
normal?
Test 6
NO
Is the flow sensor
turbine jammed?
YES
Test 7
NO
Replace the PCB assembly.
Open hot tap further/clear
strainer.
Replace the PCB assembly.
YES
Free the flow sensor turbine.
Replace the water flow sensor.
874W Series models are not
suitable for use as in-series gas
boosters.