Interlock Switch Assembly - Amana CRC18T2OG Service Manual

Hide thumbs Also See for CRC18T2OG:
Table of Contents

Advertisement

Disassembly
!

Interlock Switch Assembly

1. See "Component Location" Figure 1, for location.
2. Unplug power cord from power source.
3. Remove outer case.
4. Disconnect wiring.
5. Remove screws securing switch assembly to unit.
6. Install new switch assembly.
7. Install screws but do not tighten.
8. Proceed to "Door/Interlock Switch Adjustment" procedure.
NOTE: When the line fuse is blown replace interlock switch assembly.
R0150154 Early Production Switch
Mounting
screws
WARNING
Monitor
Primary
Logic
Secondary
12538901Q Later Production Switch
Mounting
Screws
To avoid the risk of electrical shock, personal injury, or
death, disconnect power to oven and discharge
capacitors before following any disassembly procedure.
R0000277 Replacement for Early Production Switch
Mounting
screws
Primary /
Logic
Monitor
Secondary
27
Primary
Logic
Monitor
Secondary
RS2240002 Rev. 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents