Scheduling Menu Mode - Honeywell VISTA-128BPT Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
Example of Open/Close Exception Reporting & Scheduling
The following chart gives an example of how the Open/Close by Exception reporting works.
6:01PM
5:59AM
Early Opening reports are
sent if system is manually
disarmed before opening
window begins.
Early and Late Opening
and Closing reports are
programmable options
in the Report Code
Programming. They are
not dependent on the
programming of the
Exception Reporting
option.

Scheduling Menu Mode

The #80 Scheduling Menu Mode is used to program most of the scheduling and timed-event options. Enter Installer
Code + [#] + [8] + [0] from the normal operating mode. NOTE: Only users with an Installer or Master level user code
may enter the #80 mode.
The following can be programmed while in this mode:
time windows
open/close schedules to each partition
holiday schedules
Time-Driven events (for system functions and relay activation)
limitation of access schedules
Some scheduling features are programmed in Data Field Programming Mode (Installer Code + 8 0 0 0). Some features
are programmed in the #93 Menu Mode. The programming scheduling fields are listed below.
System-Wide Fields:
∗04
Enable Random Timers
Relay timeout values
1∗74 –1∗75
Daylight saving time options
2∗01-2∗02
Allow disarming outside window if alarm
2∗11
occurs
Partition-Specific fields:
Auto-arm delay value
2∗05
Auto-arm warning time
2∗06
Auto-disarm delay value
2∗07
Force-arm enable
2∗08
Open/Close Reporting by Exception
2∗09
Restrict disarm only during windows
2∗10
#93 Menu Mode (System Group #3)
Scheduling related report codes
Event-driven options are programmed using Output Programming in #93 Menu Mode. Relay activation can also be Time-
Driven and that those are programmed using the #80 Menu Mode. Refer to the Time-Driven Event Programming later
in this section for the procedure.
Steps to Program Scheduling Options
This section contains examples of the worksheets only. For complete worksheets, see the Programming Guide
accompanying this Installation and Setup Guide.
6-4
6AM
9AM
9:01AM
Auto-disarm delay begins.
Opening Window
Auto-disarm occurs after delay (if
No reports are sent if
auto-disarm is enabled).
system is disarmed
Missed Opening reports are sent
during this time
if manual disarming has not
window.
occurred at expiration of opening
If an arming occurs,
window.
a Closing report is
Late Opening reports are sent if
sent to the central
disarm occurs after the opening
station regardless of
window expires.
how the Exception
Early Closing reports are sent if
Reporting option is
manual arming occurs before the
set.
closing window begins.
Missed Opening/Closing type
reports are programmed in the
Report Code Programming.
The Exception Reporting
option must be set for these to
be sent.
3:59PM
4PM
Closing Window
No reports are sent
if system is armed*
during this time
window.
* or disarmed if
user needs to re-
enter premises.
6PM 6:01PM
5:59AM
Auto-arm delay begins.
Auto-arm warning begins.
Auto-arm occurs after
warning expires (if auto-
arm is enabled).
Missed Closing reports are
sent if manual arming has
not occurred at expiration
of closing window.
Late Closing reports are
sent if system is manually
armed after the closing
window expires.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia

Table of Contents