Mercantile Safe And Vault Listing Guidelines; Installing The Control's Circuit Board; Figure 3-2: Cabinet Attack Resistance Considerations - Honeywell VISTA-128BPT Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
U LC
24-Hour audible alarm (Zone types 6 and 7) is not approved for ULC application.
All wiring between the bell and panel must be run in conduit. Remaining wires do not need to be run in conduit.
All wiring that is not run in conduit must exit from the knockout openings on the bottom or back of the cabinet.
All unused knockouts must be plugged using the disc plugs and carriage bolts (supplied), as indicated in the
diagram below.
Fasten the cabinet door to the cabinet backbox using the 18 one-inch-long Phillips-head screws (supplied) after all
wiring, programming, and checkout procedures have been completed.
RUN BELL WIRES
IN CONDUIT
PLUG THIS
KNOCKOUT
PLUG THIS
KNOCKOUT

Mercantile Safe and Vault Listing Guidelines

Follow the guidelines given above for Mercantile Premises listing.
Mount a shock sensor such as the System Sensor ASC-SS1 to the control's backbox. Follow the manufacturer's
instructions for proper sensor mounting. This sensor also must be wired to a hardwire zone.
For safe and vault applications, a UL Listed contact must be used inside the cabinet through one of the knockouts
for pry-off tamper purposes. This sensor also must be wired to a hardwire zone.

Installing the Control's Circuit Board

To install the circuit board in the cabinet, perform the following steps:
Step
Action
Hang the three mounting clips on the raised cabinet tabs. Refer to Figure 3-3 (Detail B).
1
Make sure the clip orientation is exactly as shown in the diagram to avoid damage. This will also avoid
problems with insertion and removal of the PC board.
Insert the top of the circuit board into the slots at the top of the cabinet. Make certain that the board rests in
2
the slots as indicated (Detail A).
Swing the base of the board into the mounting clips and secure the board to the cabinet with the
3
accompanying screws.
NOTES:
Make certain that the mounting screws are tight. This ensures that there is a good ground connection between the
PC board and the cabinet.
Dress field wiring away from the microprocessor (center) section of the PC board. Use the loops on the left and right
sidewalls of the cabinet for anchoring field wiring using tie wraps (Detail C). These steps are important to minimize
the risk of panel RF interference with television reception.
3-2
PLUG THIS
KNOCKOUT
CLIP-ON DOOR
TAMPER SWITCH
CABINET
PC
MOUNTING
BOARD
HOLE
(4 PLACES)
PLUG THIS
KNOCKOUT
RUN ALL REMAINING
WIRE THROUGH HERE

Figure 3-2: Cabinet Attack Resistance Considerations

TO PLUG AN UNUSED KNOCKOUT OPENING,
REMOVE KNOCKOUT AND INSTALL A PAIR OF
DISC PLUGS AND A CARRIAGE BOLT AS SHOWN.
KNOCKOUT
OPENING
HEX NUT AND
WASHER
DISC PLUGS (DIMPLES IN DISC
PLUG SHOULD REGISTER INSIDE
KNOCKOUT OPENING)
CARRIAGE BOLT
CABINET SIDE WALL
(OUTSIDE)
cabattack-001-V1