To install the relay modules, see Figure 3-19 and perform the following steps:
Step
Action
1
Set the 4204 DIP switches for a device address 01-15.
Do not use an address being used by another device (keypads, RF receivers, etc.).
2
Mount the 4204 Module per the instructions provided with them.
3
Connect the module's wire harness to the control (6, 7, 8, and 9). Plug the connector (other end of harness) to
the module.
If you are mounting remotely, homerun each module to the control. The table below shows the maximum wire
run lengths.
Wire Gauge
#22
#20
#18
#16
OFF
Installing 4101SN Relay Modules
The 4101SN V-Plex Single Output Relay Module is a serial number polling loop output device. The 4101SN features the
following:
Form C relay contacts rated at 2A, 28VAC/VDC with contact supervision.
The position of the relay is supervised, but not the actual external contact wiring.
One class B/style B EOLR-supervised auxiliary input zone.
Operating power and communication with control panels via the V-Plex polling loop.
Electronics mounted in a small plastic case with tamper-protected cover.
Connect the device to the polling loop, terminals 24 (+) and 25 (-). Be sure to observe polarity.
3-18
Maximum Length
125 feet
200 feet
300 feet
500 feet
DIP SWITCH SETTINGS
SWITCH
ON
NUMBER
0
1
2
3
4
5
6
2
ON — ON — ON — ON — ON — ON — ON — ON —
3
ON ON — — ON ON — — ON ON — — ON ON — —
ON ON ON ON — — — — ON ON ON ON — — — —
4
5
ON ON ON ON ON ON ON ON — — — — — — — —
6
ON ON ON ON ON ON ON ON
DIP SWITCH (WHITE AREAS DENOTE SWITCH HANDLES)
POSITION 7: NO FUNCTION
POSITIONS 2-6:
DETERMINE 4204'S ADDRESS: CONTROL'S INSTRUCTIONS SPECIFY ADDRESS
TO USE. "0" ADDRESS SETTING SHOWN (AS SHIPPED).
POSITION 1: ENABLES/DISABLES COVER TAMPER. ON = TAMPER DISABLED,
OFF = TAMPER ENABLED. SHOWN DISABLED AS SHIPPED.
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
4-PIN TOUCHPAD PLUG
EITHER OR BOTH
CAN BE USED
13
14

Figure 3-19: 4204 Relay Module

4204 ADDRESS SETTINGS
("—" means "OFF")
8
9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
7
ON — ON — ON — ON — ON — ON — ON — ON —
ON ON — — ON ON — — ON ON — — ON ON — —
ON ON ON ON — — — — ON ON ON ON — — — —
ON ON ON ON ON ON ON ON — — — — — — — —
— — — — — — — —
ON ON ON ON ON ON ON ON
RELAY
4
TYPICAL
(SHOWN "OFF")
RELAY
3
RELAY
2
RELAY
TB1
1
15
16
DATA IN
YEL
FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT
TO CONTROL
RED
(+) 12V
— — — — — — — —
C
NC
NO
C
NC
NO
RELAY CONTACTS ARE
NOT SUPERVISED
C
NC
NO
C
NC
NO
TB2
4204 CONNECTIONS
4204-005-V0