Trouble
LEAKING WATER PAN
FIGURE 15
NOTE: Remove pump tubing from the dump solenoid, after the pump has been lifted out of the res-
ervoir, disconnect the distributor tubing at the tee fitting and lift pump out.
ICE WILL NOT HARVEST
TP00952
Probable Cause
A.
Damaged water pan.
Pull tab toward you.
A.
Grid separation.
B.
Defective plating.
A.
Turn pump clockwise and lift.
A.
B.
40
Xtreme Ice Training Manual
Remedy
Replace water pan (see Kit
Instructions, number below, for
Water Pan Replacement).
Model #
Kit #
300
631500152
500/600/800/1000 631500153
1200
631500154
Replace evaporator (see Kit
Instructions, number below, for
Evaporator Replacement).
Replace evaporator (see Kit
Instructions, number below, for
Evaporator Replacement).
Model #
Kit #
300
631500121
500
631500119
600/800/1000
631500135
1200 Right
631500119
1200 Left
631500141