Yate production dryers
Table of Contents

Advertisement

ARISTON
Rear NTC fault
STATE
Resistance NTC open
or short circuit.
ARISTON
Upper heater relay welded closed
STATE
Upper resistance is
ON even when it is not
driven.
ARISTON
Master relay welded
This fault appears after 20 minutes.
STATE
Master relay welded
closed
Service Manual
Yate Production Dryers
FAULT 13
CORRECTIVE ACTIONS
Check resistance value of the NTC. It
should be about 500 kOhms in room
temperature.
Check state of the connectors.
Check continuity and state of the
wiring.
FAULT 15
CORRECTIVE ACTIONS
FAULT 17
CORRECTIVE ACTIONS
INDESIT
INTERVENTION TO BE PERFORMED
- Replace the NTC.
- Clean and refi t.
- Change the wiring.
- Replace the main board.
INDESIT
INTERVENTION TO BE PERFORMED
- Triac in cort circuit; replace the main board.
INDESIT
INTERVENTION TO BE PERFORMED
- Replace the main board.