Component Identification
Integrated Air Controls
D200, D200s, D60, and S20 Models
The integrated air controls include:
•
Main air slider valve (BA): turns air on and off to
the system. When closed, the valve relieves pres-
sure downstream.
•
Ram air regulator (BB): controls ram up and down
pressure and blowoff pressure.
•
Ram director valve (BC): controls ram direction.
•
Exhaust port with muffler (BD)
•
Air motor regulator (BE): Controls air pressure to
motor.
•
Air motor slider valve (BF): turns air on and off to
the air motor. When closed, the valve relieves air
trapped between it and the air motor. Push the valve
in to shutoff. Remote DataTrak: The air solenoid
(X, F
. 1), the air motor slider valve (BF), and the
IG
main air slider valve (BA) must be open for air to
flow. (See Remote DataTrak Setup, page 23.)
•
Blowoff button (BG): turns air on and off to push
the platen out of an empty drum.
BG
BA
F
. 3. Integrated Air Controls
IG
12
BF
BE
BD
BC
BB
ti10438a
Air Line Accessories
See F
. 1.
IG
•
Air line drain valve (U)
•
Air line filter (V): removes harmful dirt and mois-
ture from compressed air supply.
•
Second bleed-type air valve (W): isolates air line
accessories and supply system for servicing. Locate
upstream from all other air line accessories.
•
Air relief valve (attached to ram air regulator, not
visible): automatically relieves excessive pressure.
2-Button Interlock Air Controls
D60i, D200i, and D200si Models
Units that have 2-Button Interlock controls have the fol-
lowing additional components:
•
2-Button Module: See manual 312374 for
information.
•
Roller switch (CA): shuts off air supply when it con-
tacts the bracket actuator. Operator must push and
hold the activation buttons simultaneously to
resume ram movement.
F
. 4
IG
•
Bracket actuator (CB): attaches to the platen lift
rod. When platen is outside of drum, actuator makes
contact with the roller switch.
CA
CB
F
. 5
IG
Activation
Buttons
ti10843a1
ti10846a