Remote Datatrak Operation; Startup; Run Mode - Graco L20c Operation

Supply systems
Hide thumbs Also See for L20c:
Table of Contents

Advertisement

Remote DataTrak Operation

Startup

1. Turn the air motor slider valve (BF) off before turning
the remote DataTrak power on.
NOTICE
If the motor air valve is not turned off, the air supply to
the motor will automatically turn on via activation of
the air solenoid (X) when the display changes from
the Splash screen to Run mode.
2. Turn on the remote DataTrak system using the
rocker switch on the ram power supply.
F
. 17
IG
3. The Splash screen (F
progress bar fills from left to right. It will then go
directly to Run mode (F
4. Follow the Start and Adjust Pump procedure in the
pump manual.
F
. 18: Splash Screen
IG
ti10433a
ti10433a
. 18) will flash on while the
IG
. 19).
IG

Run Mode

See F
. 16 and F
. 19.
IG
IG
The Run Mode screen displays the resettable job total
counter (JT), maintenance counter (MC), cycle/flow rate
(CF), and the remaining volume in the drum (DV) in both
numeric and icon versions.
All items are displayed using the defined volume
units (VU).
DV
CF
F
. 19: Run Mode Screen
IG
Key Functions When in Run Mode
1. To enter Prime Mode, press and release
2. To enter Setup Mode (page 26), press and hold
for 3 seconds.
3. To enter Diagnostic Mode (page 29), press and
release
. The system will enter Diagnostic Mode
only if there are active warnings/alarms.
4. To reset the job total counter, press and hold
from Run Mode for 3 seconds.
Remote DataTrak Operation
JT
MC
.
25