Remote DataTrak Setup

The remote DataTrak display unit comes fully assem-
bled. Use the following instructions and figure to connect
remote DataTrak to the supply system.
The system requires either 100-240 Vac, 50/60 Hz input,
or 24 Vdc to the power supply. Ensure that the main dis-
connect rocker switch is set to OFF (O). Connect power
to the DataTrak unit as detailed in Connect Remote
DataTrak Units to Power, page 16.
1. Feed CAN cable (HB) and D-Sub cable (HA) under
the remote DataTrak bracket and attach to corre-
sponding connectors on remote DataTrak display.
The CAN cable (HB) can connect to either of the
two CAN style connectors on the remote DataTrak.
2. Snap remote DataTrak unit to mount on ram supply
system.
HA
HB
F
. 14: D200, D200s, and D60 supply systems
IG
HA
connector
F
. 15: S20 supply systems
IG
3. Drum Low/Empty Sensor: If system has this fea-
ture, attach sensor cable to the corresponding con-
nector on the D-Sub harness. See Drum
Low/Empty Sensor, page 15.
4. Light Tower: If system has this feature, attach the
X
connector on the light tower cable to the corre-
sponding connector on the D-Sub harness. See
manual 312493.
BF
5. Solenoid: Attach the connector on the D-Sub har-
ness to the corresponding connector on the sole-
noid (X).
ti10431a
Supply System Operation
HB connector
X
BF
r_cm9hlb_313526_6a