Samsung SCX-5530FN/XAZ Service Manual page 94

Digital laser mfp scx-5x30 series
Table of Contents

Advertisement

Disassembly and Reassembly
5.6 Fuser Ass'y
1. Before you remove the Fuser Ass'y, you should open
the face up cover and open the guide output fuser.
- Rear Cover (Refer to 5.5)
2. Remove the four screws securing the Fuser Ass'y and
then pull the Fuser Ass'y.
3. Release the CON Harness and REC Harness from
the Thermostat and then remove the three screws
securing the Thermostat and remove it.
REC Harness
Service Manual
5-6
Fuser Ass'y
Thermostat
CON Harness
4. To remove the Electrodes, first release REC Harness
from the left side of the Electrode and then release the
CON Harness from the right side of the Electrode, as
shown below.
REC Harness
5. Remove the two screws securing the both side of the
Electrode and then release the Caps and Electrodes
in the direction of arrow, as shown below.
Cap
Electrode
CON Harness
Electrode
Cap
Samsung Electronics