Power Module

1.
Release front access flap as in E). and release harness retaining clip before hinging down.
2.
Slide power module towards connections to release from access panel.
3.
Note position and remove connections.
4.
Release board from carrier.
Note: A Service Module is supplied WITHOUT a programme loaded.
Refer to the Module Programming section in this manual.
Ensure that the harness is
clipped back into place when
the flap is closed
G. Base Unit Access Panel
1.
Protect the customers flooring
2.
Being careful not to damage the waste hose, carefully lay the machine on its back.
3.
Remove any screws that may have been fitted to replace broken clips.
4.
Release 2 fixing clips on front edge.
5.
Ease panel forwards releasing lugs from rear of panel.
Locking Tabs
Service Manual UK
Front Access panel opens out with Control Module Attached.
Access panel removed