Batteries - Clarke CA30 20B Service Manual

Hide thumbs Also See for CA30 20B:
Table of Contents

Advertisement

Service Manual – Clarke CA30 20B and 17E

Batteries

Caution: Care must be taken to avoid shorting the battery terminals or battery wires. Never rest tools
on top of the batteries, as they can contact and short across the battery terminals.
1. Remove the Squeegee Assembly.
2. Remove the
Rear Covers (Control Cover)
26.
• For battery access, only the lower cover need be removed.
Remove the 2 screws marked (D) in the procedure.
• Remove the squeegee lift cable (F) in the procedure.
• Unplug the main battery disconnect in the procedure.
3. Route the vacuum hose (A) and recovery drain (B) through
the operator's handle to keep them out of the way during the
procedure.
4. Remove the 2 screws (C) that secure the battery
retaining bracket (E), and remove the bracket.
5. Position a platform or lift (G) in back of
the machine that matches the height of the
battery compartment.
6. Simultaneously slide both batteries (H) out of
the machine and onto the lift.
• The batteries are not mechanically joined,
but they are connected by the rear battery
cable, and must be moved together.
described on page
C
Control System (Battery Model)
B
A
F
E
H
G
30
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca30 17e

Table of Contents