5.5.2

Optical attachments to Industrial Ethernet

5.5.2.1

Multimode fiber-optic cable

Transmission medium
The following X-200 IE switches use multimode fiber-optic cables as the transmission
medium:
● X204-2
● X204-2TS
● X204-2FM
● X206-1
● X212-2
● XF204-2
● XF206-1
● X202-2IRT
Characteristics:
Transmission speed
Transmission mode
Connectors
Wavelength
Core diameter
Outer diameter
Light source
Maximum range (segment length)
Note
No autonegotiation
With optical transmission, the full duplex mode and transmission speed cannot be changed.
For this reason, the autonegotiation function cannot be selected.
SCALANCE X-200
Operating Instructions, 03/2015, C79000-G8976-C284-06
5.5 Attachment to Industrial Ethernet
100 Mbps
100Base-FX according to IEEE 802.3
BFOC sockets
1310 nm
50 or 62.5 μm
125 μm
LED
5 km